Trane, in offering the Trane Air Conditioning Economics
(TRACETM700) computer program, accepts no
responsibility or liability for the design of buildings or their support systems
or for the accuracy of the economic analysis and the building and system air
conditioning load data. The economic analysis and the building and system air
conditioning load data are based on conventional economic and engineering
principles, plus financial and engineering data supplied only by the program
user. This TRACE 700 program is intended to be used as a comparative study of
operating efficiencies and costs of alternative air conditioning systems. Trane
further accepts no responsibility or liability for the suitability of the
building air conditioning system in providing proper temperature control,
humidity control, infiltration, air distribution and quiet operation.
Release
6.0
Release 6.0.0 was distributed via CD to all active TRACE 700
customers January, 2006.
New Features
(General)
- System-level ventilation inputs.
- ASHRAE recommended RTS cooling methodology based on Heat Balance and
ASHRAE Tables.
- Dedicated outdoor air units can now dehumidify and reheat the air to room
neutral conditions.
- Energy recovery devices have been added to model series and parallel
supply air tempering (i.e., heat pipe).
- Additional options available for energy recovery devices (i.e., bypass
dampers, additional static, fan energy, etc...).
- Dual path airhandlers (Split Dehumidification Unit).
- Direct control of room humidity by reheating supply air.
- Checkbox that will reset the vav minimums so they are large enough to
handle the ventilation requirement.
Enhancements
- Heat recovery effectiveness value is now variable.
- Internal loads, glass, materials, construction types, and internal and
external shading libraries have all been expanded.
- All reports have been updated.
- Getting started manual has been updated.
Back
to top
[Version 6.1, T7up61.exe] 10/12/06
This
update contains the following items:
- Added ASHRAE Standard 62.1-2004 ventilation calculations.
- Added ability to model shutoff vav boxes to certain zones connected to a
fan powered system (for example, interior zones).
- Added ability for series heat recovery devices to handle additional
requirements from dedicated OA units.
- Program will no longer recalculate to determine the worst case room
relative humidity unless the user has selected Direct Dehumidification. This
will significantly reduce calculation time.
- Fixed an error that occured if an exposed floor was entered and the
methodology was RTS.
Back
to top
[Version 6.0.2.1, T7up6021.exe]
03/20/06
This update contains the following items:
- Added *Template to component tree view for humidity fields.
- Added feature to allow user to turn off partition import from gbxml.
- Removed the print confirmation dialog.
- Fixed economizer fields in the component tree view.
- Fixed conversion of version 4 files to version 6.
- Fixed energy recovery effectiveness values that came in as negative.
- Fixed fan heat calculations.
- Fixed problem where some files were crashing with RTS methodology.
- Fixed the Retest Peaks calculation.
- Fixed the energy recovery at design tonnage reduction when an energy
recovery device was used on a dedicated OA unit.
Back
to top
[Version 6.0.01, T7up601.exe] 01/10/06
This
update contains the following items:
- Fixed energy recovery for VTCV in heating mode.
Back
to top
Release
4.1
Release 4.1.0 was distributed via CD to all active TRACE 700
Load Design customers December, 2002.
New
Features
- New File Wizard: Provides the ability to generate a block building
- The ability to apply Weather Overrides to entire year, rather than just to
the user defined “summer months”.
- Weather Overrides based on the peak DB and coincident WB in the weather
file rather than the information on the General Information tab. Both sections
were updated so that both values now match.
- Option to refresh construction types and glass types in the input section.
- Message listing all rooms that are missing library members during
calculation.
- Heating Coils section of the Checksums has been modified in an attempt to
better explain where the loads involved in coil sizing are coming from. Four
output fields were added: OA Preheat Diff, RA Preheat Diff, Additional Reheat
and System Plenum Heat (see "Heating Coil Calculations.doc" for more details).
- Added new systems types: VRV, VENTHTG, VARITRAC.
- Added capability to account for EAHR at design.
- Ability to account for Reheat Temperature Difference during Cooling
Design.
- Archive utility to save project file with custom library members.
- Templates included as a step (icon) of the Project Navigator.
- Ability to create and compare up to 4 alternatives.
- Not necessary to confirm file saving everytime user exits the program or
file.
- New updated help file.
Back
to top
[Version 4.1.11, T7up4111.exe]
03/03/05
This update contains the following items:
- Modified Entered Values reports.
- Modified length of combo boxes to fit longest name.
- Fixed problem when Defualt templates were renamed.
- All reports converted to use new Crystal 10.
- Modified System Exhaust value on System Component Selection
report.
Back
to top
[Version 4.1.10, T7up4110.exe]
11/12/04
This update contains the following items:
- Modified Daylight Savings calculations.
- Corrected R/OA temperature calculation for Optional Vent units.
Back
to top
[Version 4.1.9, T7up419.exe] 08/27/04
This
update contains the following items:
- Changeover Bypass system now calculates heating coil for block airflow
instead of peak.
- Increased the amount of Coefficients used in calculating the construction
type properties.
- Modified the Return/OA temp calculation for systems sized on Sum of Peaks.
- Modified Std 62 calculations for constant volume systems.
Back
to top
[Version 4.1.7, T7up417.exe] 06/17/04
This
update contains the following items:
- Fixed cloud cover modifier when importing 8760 weather.
- Fixed import of 8760 weather that contained unknown/blank data fields.
- Added ability to choose which components to be imported with GBxml import.
- Fixed metric conversion of humidity ratio.
- Added msxml4 dlls required for GBxml import and export.
- Added further GBxml error checking.
Back
to top
[Version 4.1.6, T7up416.exe] 04/16/04
This
update contains the following items:
- Updated the cloud cover multiplier calculation.
- Numerous additions to gbxml import and export feature.
- Fixed ventilation methodology flag.
- Added metric capability to New File Wizard.
- Fixed New File Based On handling of zones.
- Updated CEC-DOE Cooling Methodology.
- Fixed ASHRAE STD 62 ventilation calculation when an optional vent units
was selected.
- Fixed problem with too many external shading types.
Back
to top
[Version 4.1.5, T7up415.exe] 03/05/04
This
update contains the following items:
- New license agreement.
- Added Library Management tool allowing a user to hide old library members
and the members with an EQ description.
- Added Flag to convert fan schedules to Available 100%.
- Added choice to Archive file from the start up screen.
- Fixed special 8760 excel report.
- New System Component Selection Report.
- Added Export GBXML option.
- The weather generate tool was incorrectly using a constant humidity ratio
for the entire day. Fixed so it generates the wet bulbs given the user's value
of constant relative humidity.
- Fixed OV coil selection info not showing up on the checksums for VAVBSK.
- Fixed bug associated with adding a skin htg sub-system (auxiliary heating
coil) to a VRH system that undersized the skin htg coil.
- User defined Preheat Coil temperatures no longer allowed.
- ASHRAE 62. Per a coding change on 12/13/2002, TEMP was ignored when Z=1.
Code changed back.
- New lighting and Miscellaneous load values applied to New File Wizard
templates.
- Fixed problem for all system types when an enthapy wheel or runaround loop
is combined with an economizer.
- Fixed problem where OV coil selection info is not showing up for VAVBSK in
the checksums.
- Fixed problem where the wrong ventilation airflow was reported on the
Design Airflow report.
Back
to top
[Version 4.1.3, T7up413.exe] 10/30/03
This
update contains the following items:
- Added feature allowing multiple files to be merged into one.
- Fixed the external shading type Adjacent Building.
- Fixed the main heating calculation for the Bypass VAV with Reheat system.
- Added new system type Changeover-Bypass VAV with Reheat.
- Added new system type Changeover-Bypass VAV with Local Heat.
- Added feature to ratio the coil airflow when a space Block airflow is
specified.
- Changed the way the Building Peak value is calculated.
- Fixed problem where the Changeover Bypass Vav system was not eliminating
the bypass airflow properly during fan cycling.
- Added feature for the database to scan only the alternatives that are
required to calculate (decreases calculation time).
- Changed the fan sizing method for the Changeover-Bypass system from Peak
to Block.
- File extension is now included when the File Save As command is used in
the Load 700 and Load Express mode.
- Floor multiplier is allowed for Load 700 mode.
- Increased the size of the wall and roof construction fields.
- Increased the size of the templates field.
- New message box applied when calculation occurs with nothing selected to
calculate.
- Added restriction where at least one Monday must be input per month in the
calendar.
- Fixed problem with the roof import from GBXML.
- Removed external shading from roofs.
- Modified the heat recovery calculations.
- Fixed oversizing value with Terminal Reheat system.
- Fixed problem with liquid dessicant heat recovery.
Back
to top
[Version 4.1.2, T7up412.exe] 6/24/03
This
update contains the following items:
- Fixed problem allowing VAV Min stop inputs to be equal to or less than
Supply Airflow.
- Fixed problem where Oversizing was being double accounted for on a
terminal reheat system.
- Fixed Heating Design numbers for Double Duct Multizone system.
- Fixed the "Tab" order on New File Wizard, so a user can tab between all
fields.
- Fixed ASHRAE STD62 calculation when rooms with differing Setpoints were
assigned to the same system type.
- Added ability to change program mode to Trace 700 Load Express
- Added Roof to the internal room on the block building in New File Wizard.
- Added two decimal places for airflows on the room entered values report.
- Added Reheat design capacity values for VAVBSK and VAVFSK.
- Adding a static pressure activates the Apply button.
- When a file is renamed, it requires that all sections are recalculated.
- Program checks for empty zones and restricts calculation if one is found.
- Archive utility includes schedules used in a template even if they are not
used in the file.
Back
to top
[Version 4.1.1, T7up411.exe] 4/1/03
This
update contained the following items:
- Fixed problem when a file using 8760 weather was run twice without change.
- Fixed units issue with global airlfow templates.
- Fixed a reporting issue in the Rooms entered value report.
- Fixed the % glass solar to retun air calculation when using VAV systems.
- Fixed auxiliary heating airflow for VAV forced flow skin heating.
- Fixed problem with optional ventilation supply air temperatures.
- Fixed the reheat temperature difference calculation when a leaving cooling
coil temperature is specified.
- Added a "special character" check within the file.
- Added check to to verify glass area is less than wall area.
- Added prompt if .taf file already exists.
- Added feature allowing GBXML import to an exisitng file.
- Added feature allowing the optional ventilation heating supply temperature
to be higher then the cooling supply air temperature when ventilation deck is
room direct.
- Added a New File Based On feature allowing a user to create a new file by
using an alternative from a different file as the base case.
- Added an option to replace or leave custom library members when an
archived file is opened and contains a library member with the same name as
one stored in the lib7.db.
- Added an AND flag to the reset and lockout schedules.
- Added a Print Option for checksums reports allowing a user to preview only
the rooms, zones, or systems of interest.
- Added feature to apply weather overrides to the entire year.
- Added Reccessed Windows as an external shading type.
- Modified the psychrometric state points reports.
- Modified the ASHRAE standard 62 algorithm.
- The Archiving a project feature was changed to include only the custom
library members within the file
- A new Library Members report was created that lists out all of the library
members used in the Trace project. It contains all of the custom and standard
library members as well as the information contained within them.
- Room heating setpoint can be specified higher than the room cooling
setpoint for design purposes.
Back
to top